Home > Hipath 3000 > Hipath 3000 Error Messages

Hipath 3000 Error Messages

manual Siemens HIPATH HIPATH 3000 Operating Instructions Manual: Responding To Error Messages On The Screen; Contacts For Resolving Problems Siemens telephone user manual. Hide thumbs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 Step by Step US: Invalid entry UK: Incorrect entry US: Not authorized UK: Access denied US: Currently not possible UK: Feature not available US:Invalid station number UK: Number cannot be dialed US: Key memory is full UK: Max.no.of keys exceeded Responding to Error Messages on the Screen Possible cause: The station number is incorrect. Possible response: Enter a correct station number. Possible cause: You tried to activate a disabled function. Possible response: Ask System Support to authorize you to use the func- tion. Possible cause: The station number you dialed does not exist. The tele- phone you are trying to call is unplugged. Possible response: Enter a correct station number. Try calling the telephone again later on. Possible cause: You dialed your own station number. Possible response: Enter a correct station number. Possible cause: All memory locations for external station numbers are currently in use. Possible response: Try again later on. Contacts for Resolving Problems If you encounter a problem that lasts longer than five minutes, contact System Support. Fixing Problems 101 Table of Contents Service(hipath3500/3550/3700/3750Only) TransferringCallForwarding Previous page Next page 1...99100101102103 Related Manuals for Siemens HIPATH HIPATH 3000 Telephone Siemens HiPath 4000 Operating Instructions Manual (5

economy User Manual: Responding To Error Messages On The Screen Hipath 1220. Hide thumbs Also See for optiPoint 500 economy User manual - 104 pagesOperating instructions manual - 141 pagesOperating instructions manual - 133 pages 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 http://www.manualslib.com/manual/152668/Siemens-Hipath-Hipath-3000.html?page=101 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 Step by Step Invalid entry Not authorized Not possible Cannot be reached Invalid station number Key memory is full Memory is full Currently not possible Incomplete 80 Responding to Error Messages on the Screen Possible cause: Wrong number/code. Possible response: Enter the https://www.manualslib.com/manual/894096/Siemens-Optipoint-500-Economy.html?page=80 correct number/code. Possible cause: You tried to use a disabled function. Possible response: Ask the service personnel to enable the function. Possible cause: Wrong number/code. Possible response: Enter the correct number/code. Possible cause: The station number you dialed does not exist. The tele- phone you are trying to call is unplugged. Possible response: Enter a correct station number. Try calling the telephone again later on. Possible cause: The number you dialed, for example on call pick-up or group number Possible response: Enter the correct number. Possible cause: All memory locations for external station numbers are currently in use. Possible response: Try again later on. Possible cause: The function is temporarily unavailable (for example, af- ter pressing the mute key while the telephone is idle). Possible response: Press the mute key during the call. Possible cause: You took too long to enter data. Possible response: Try again later on. Previous page Next page 1...767778798081828384 Also See for Siemens optiPoint 500 economy Siemens HiPath 500 Operating Instructions Manual 141 pages Siemens HiPath 500 Operating Instructions Manual 133 pages SIEMENS HiPath 3000 Operating Instructions Manual 116 pages Related Manuals for Siemens optiPoint 500 economy Telephone Siemens optiPoint 500 economy User Manual Fo? hipath 1200

Siemens HiPath 3000 Полное описание всех ошибок станций HiPath 3000 Дата публикации: 20.07.2015 Просмотров: 1077 Строка из лога, которую видно в Manger E, имеет следующий вид: 17.11.06 02:10:46 B 26 04 07- a4 10 a4 a4 20 https://commonworkspace.ru/article.php?id=23 08 00 00 00 00 card in service В этом примере код ошибки: 26-004 !card in service The specified board is operational. None. ---------------------------------------- No. HiPath 3000 Manager E: Event Log Entry Meaning Required Measures Note Error Class 01 - General Messages 01-003 !System Restart Hard restart (reset) of entire system with current CDB. None hipath 3000 01-010 !SNMP System Restart Hard restart of entire system via SNMP. None 01-014 local DB changes "On site" changes to the database. None 01-015 remote DB changes "Remote" changes to the database. None 01-016 !SNMP APSXF result APS transfer acknowledgement message via SNMP. None 01-017 !SNMP authentication fail Unauthorized access attempt. Check firewall settings hipath 3000 error in HiPath 3000 Manager E (Network - Firewall). 01-018 !SNMP 80 % high watermark of log-file Changes logged internally in the system: 80% of write capacity used. Read out data using HiPath 3000 Manager E (Transfer - Security - Protocol). 01-019 !Sensor Alarm Temperature in HiPath 3500/HiPath 3300 19-inch housing is too high. Check the fan and air supply in the 19-inch housing. Note the ambient temperature. 01-020 !CDR buffer limit reached Overflow in the CDR buffer (CDR information). Check that the interfaces (V.24, LAN), ports and the connection are functioning or read out call data. 01-021 !Authentication Failure Unauthorized access attempt. Check firewall settings in HiPath 3000 Manager E (Network - Firewall). 01-022 !Flash deleted Flash area deleted. None APS transfer possible again. 01-023 !Process stopped Process stopped. Perform hard restart (reset). 01-024 !unauthorized application Attempted access via an unauthorized application. Check firewall settings in HiPath 3000 Manager E (Network - Firewall). 01-025 !manual switchback from HiPath Manager Error Class 02 - License M

 
No related pages.